Philips Lisse hair straightener won't turn on, is completely dead, indicator lights not illuminating, ceramic plates fail to heat up, or experiences sudden power loss due to a worn-out swivel cord or a tripped internal thermal fuse.
Disassembled the handle casing to perform detailed electrical continuity tests on the 360-degree swivel cable, power switch, and circuit board. Replaced the faulty internal thermal fuse and damaged power wiring to restore full heating performance and power flow.